Diagnostics of Transient States in Hydraulic Pump System with Short Time Fourier Transform
More details
Hide details
1
Department of Automation, Faculty of Mechanical Engineering, Lublin University of Technology, Nadbystrzycka 36, 20-618 Lublin, Poland
Publication date: 2020-03-01
Corresponding author
Krzysztof Przystupa
Department of Automation, Faculty of Mechanical Engineering, Lublin University of Technology, Nadbystrzycka 36, 20-618 Lublin, Poland
Adv. Sci. Technol. Res. J. 2020; 14(1):178-183
KEYWORDS
TOPICS
ABSTRACT
In hydraulic pump system various states can occur caused by mechanical and physical phenomena. To detect them, the Short Time Fourier Transform (STFT) is applied. This paper will consider an application of STFT to monitor and evaluate hydraulic pump system operation in different states of operation. For measurements of pressure and flow changes in pump, hydraulic tester and DAQ card was used for evaluation of qualitative and quantitative changes in the system. Results of hydraulic pump’s operation will be shown on Fast Fourier Transform (FFT) charts and STFT spectrograms plots.